Por favor, use este identificador para citar o enlazar este ítem:
http://ri.ufrb.edu.br/jspui/handle/123456789/2856
metadata.dc.type: | Trabalho de Conclusão de Curso |
metadata.dc.degree.level: | Bacharelado |
Título : | Estudo de concepção para expansão da rede de distribuição de água no Campus Cruz das Almas (UFRB) |
metadata.dc.creator: | Santos, Eugenio Rodrigues Bispo dos |
metadata.dc.contributor.advisor1: | Almeida, Rosa Alencar Santana de |
metadata.dc.contributor.referee1: | Botelho, Gabriella Laura Peixoto |
metadata.dc.contributor.referee2: | Souza, Elves de Almeida |
metadata.dc.description.resumo: | O abastecimento de água potável, componente fundamental dos serviços de saneamento, pode ocorrer tanto por sistema de abastecimento quanto por adoção de solução alternativa. O uso de veículo transportador, que se enquadra neste segundo modo, apesar de não ser a solução mais adequada dos pontos de vista sanitário e logístico, ainda é necessário nos locais onde não existem redes de distribuição, sendo este o caso de uma área localizada no campus Cruz das Almas da Universidade Federal do Recôncavo da Bahia, na qual o veículo é responsável pelo abastecimento de 22 edificações. Deste modo, o presente trabalho teve como objetivo caracterizar o serviço de abastecimento por meio do caminhão-pipa no campus, além de discutir os aspectos legais e sanitários desta solução adotada e, por fim, propor um projeto de expansão da rede de distribuição já existente no campus como solução definitiva de abastecimento dos locais que dependem do veículo. Foi observado que o veículo é responsável pelo suprimento de uma demanda considerável de água aos locais abastecidos e que, mesmo sendo uma alternativa mais onerosa, a rede de distribuição deve ser implantada para abastecimento dos locais atendidos pelo caminhão, tendo em vista a segurança da água fornecida. A respeito da rede de distribuição, as simulações realizadas pelo EPANET 2.0 determinaram que para atendimento às recomendações de norma a pressão de entrada da rede deve ser de 16,55 mca. |
Palabras clave : | Abastecimento de água Sistemas de abastecimento Solução alternativa Saneamento básico |
Resumen : | The supply of drinking water, a fundamental component of sanitation services, can occur either through a supply system or through the adoption of an alternative solution. The use of a transport vehicle, which fits into this second mode, despite not being the most appropriate solution from a sanitary and logistical point of view, is still necessary in places where there are no distribution networks, this being the case of an area located in the Cruz das Almas campus of the Federal University of Recôncavo da Bahia, where the vehicle is responsible for supplying 22 buildings. Therefore, the present work aimed to characterize the supply service through water trucks on campus, in addition to discussing the legal and sanitary aspects of this adopted solution and, finally, proposing a project to expand the existing distribution network. on campus as a definitive solution for supplying places that depend on the vehicle. It was observed that the vehicle is responsible for supplying a considerable demand for water to the places supplied and that, even though it is a more expensive alternative, the distribution network must be implemented to supply the places served by the truck, taking into account water safety. provided. Regarding the distribution network, the simulations carried out by EPANET 2.0 determined that to comply with standard recommendations, the network inlet pressure must be 16.55 mca. |
metadata.dc.subject.en: | Water supply Supply systems Alternative solution Basic sanitation |
Editorial : | Universidade Federal do Recôncavo da Bahia |
metadata.dc.publisher.department: | CETEC - Centro de Ciências Exatas e Tecnológicas |
Fecha de publicación : | 14-ago-2018 |
metadata.dc.subject.cnpq: | CNPQ::ENGENHARIAS CNPQ::ENGENHARIAS::ENGENHARIA SANITARIA |
metadata.dc.rights: | Acesso Aberto |
metadata.dc.date.available: | 2023-10-25T21:55:09Z |
URI : | http://ri.ufrb.edu.br/jspui/handle/123456789/2856 |
Aparece en las colecciones: | CETEC - Bacharelado em Engenharia Sanitária e Ambiental - TCC |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Estudo_Concepcao_Expansao_TCC_2018.pdf | 2,33 MB | Adobe PDF | Visualizar/Abrir | |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.